  1. BGFAX's READ.ME file...  Yes, there might actually be interesting stuff here!
  2. -----------------------------------------------------------------------------
  3.  
  4. This READ.ME text file has special notes for the following configurations:
  5.  
  6. a. Auto answering
  7. b. Rockwell V.FC and V.34 modems
  8. c. FD 2.02 (free version)
  9. d. Adept-XBBS/2
  10. e. Binkley
  11. f. USR owners
  12. g. Hayes owners
  13. h. ZyXEL owners
  14. i. Supra owners
  15. j. Multitech owners
  16. k. Zoom owners
  17. l. PPI owners
  18. m. PC Logic owners
  19. n. Hornet 28.8 VFC owners
  20. o. DesqView
  21. p. OS/2
  22. q. PC Board for OS/2
  23.  
  24. ===========================================================================
  25.  
  26. Auto Answer (not Adaptive Answer)
  27. ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
  28. One quick note relating to all setups:
  29.  
  30.    Do NOT use your modem in 'auto answer' mode.  You must make your
  31.    software physically send an answer string to the modem.  Therefore,
  32.    register S0 _must_ be set to 0.  (S0=0).
  33.  
  34. Any BBS or Fido mailer software that requires the modem answer in AUTO
  35. ANSWER mode is crap.  Most software will send an answer string to the
  36. modem when the modem sends a "RING" response.
  37.  
  38. AUTO ANSWER mode forces the mode to answer the call whether your software
  39. is ready to answer it or not.  Sysops should never use auto answer.  I am
  40. making this statement because many of the setup help files (*.TXT) for
  41. BGFAX require that the BBS/mailer software send answer strings to the modem.
  42.  
  43. AUTO ANSWER is not ADAPTIVE ANSWER.  They are two different things.  Adaptive
  44. answering is required for BGFAX to receive both data and fax calls.
  45.  
  46.  
  47. Rockwell V.FC and V.34 modems
  48. ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
  49. It should be noted that many of the Rockwell V.FC modems have flawed
  50. adaptive answering.  (i.e., Many true data calls will be misinterpreted
  51. as fax calls.)  You might want to keep an eye out for this.
  52.  
  53. Many Rockwell V.34 modems suffer from the same flaw.
  54.  
  55. Supra released firmware in December 1994 that fixed Rockwell's V.34
  56. adaptive answering problem.  (This was done just before the modems started
  57. to ship, so don't worry if you have a Supra.)
  58.  
  59. Zoom released the 1.309 firmware in October 1995 that fixed Rockwell's
  60. V.34 adpative answering problem.  This was done after tens of thousands of
  61. modems have been sent out.  See the "Zoom owners" section of this file.
  62.  
  63. I am not aware of any other Rockwell based modem companies that have
  64. bothered to fix (or obtain a fix from Rockwell) on this problem.
  65.  
  66. How do you know if you have a Rockwell chipset modem?  In terminal mode,
  67. type "AT+FMFR?" to report the datapump/chipset manufactuer.
  68.  
  69.  
  70. FD 2.02 (free version)
  71. ~~~~~~~~~~~~~~~~~~~~~~
  72. I strongly recommend using FD 2.12 rather than FD 2.02.  FD 2.12 is much
  73. easier to set up with BGFAX and works much better.  FD 2.02 can be forced
  74. to work with some modems (such as the Supra), but not all of them the way
  75. FD 2.12 can be used.  Just say "no" to FD 2.02 and get FD 2.12.
  76.  
  77. I provide excellent help files for FD 2.12 that describe, in detail, what
  78. you have to do to make it work with BGFAX.
  79.  
  80.  
  81. Adept-XBBS/2
  82. ~~~~~~~~~~~~
  83. Adept-XBBS has a box on its config screen relating to whether or not an
  84. "ATO" string must be sent to the modem if it encounters a "DATA" string.
  85. This is a powerful option that has not yet made it to other mailers, but
  86. if you use this option on a modem that does not require an "ATO", you
  87. will force your modem to hangup on all data calls.
  88.  
  89. Most modems do NOT require the ATO.  Some modems in Class 1 mode require
  90. the ATO.  The Hayes Optima does NOT.
  91.  
  92. Binkley
  93. ~~~~~~~
  94. A new version of Binkley allows it to exit when a fax response is received,
  95. but it doesn't work properly with all modems.  On many Rockwell-based
  96. modems, for example, when Bink exits to run BGFAX, Bink will drop DTR which
  97. causes the modem to hangup on the fax connection.  This is not good.  :-)
  98.  
  99. This DTR problem is definately in the DOS version.  It might not be in the
  100. OS/2 version of Binkley.
  101.  
  102. However, Binkley can be used to internally receive faxes, which can then
  103. be viewed with BGFAX's VIEW.EXE program.  I recommend letting Bink do the
  104. fax receiving, mainly, because Bink is complex and I am not qualified to
  105. provide meaningful support.
  106.  
  107.  
  108. USR owners
  109. ~~~~~~~~~~
  110. Make sure DIP switch #5 is in the "SUPRESS AUTO ANSWER" position and make
  111. sure the S0 register is equal to 0.
  112.  
  113. If you plan to use BGFAX to receive both faxes and data calls, be advised
  114. that this will NOT work with the following US Robotics modems...
  115.  
  116. a. Sportster 14.4K modems (original series) because they does not have
  117.    adaptive answering.  Note that the newer Sportster VI and DSVD 14.4K
  118.    Sportsters should work, because they have both Class 2.0 and adaptive
  119.    answering.  Also, some European versions of the original series
  120.    Sportster 14.4K modems do appear to have adaptive answering, but it is
  121.    unknown as to whether it actually works or not.
  122.  
  123. b. All Courier modems slower than the 21600 v.32terbo model lack adaptive
  124.    answering.  (This means both Courier 14.4K and Courier 16.8K modems
  125.    will not be able to take both data and fax calls.)
  126.  
  127. c. The Courier 21600 v.32terbo modem does have adaptive answering and
  128.    Class 2.0 fax, but it works so badly that I do not recommend people to
  129.    use this particular modem with BGFAX.  You can call USR to buy a new
  130.    daughtercard to this modem that will upgrade it to 33600 v.34+.
  131.  
  132. BGFAX _will_ work with the 28.8K modems (V.34 Sportster/V.34 Everything).
  133. Make sure you are using firmware version 12/02/94.  (Yes, 12/02/94.  It
  134. works slightly better in fax mode than the newer 07/05/95 and 09/26/95
  135. V34+ firmware).
  136.  
  137. I have received reports, however, that some fax machines (Canon) have
  138. trouble sending faxes to the USR (Class 2.0, adaptive mode).
  139.  
  140. A few people have sent me reports that indicate the 07/05/95 firmware may
  141. have additional fax problems (Sharp fax machines).
  142.  
  143. Ignore anything the USR manual says about fax commands.  Also, it is normal
  144. for the FAX/ARQ light to "blink" when the modem is waiting for a fax call.
  145. The blinking means the modem is in "adaptive answering" mode.  (NOTE: It is
  146. NOT normal to blink when a user is online.  If that is happening, it means
  147. you have a noisy connection.)
  148.  
  149. If you are using one of the DUAL STANDARD Courier modems, you may need to
  150. put a "B0" in your answer string to make sure the modem is prepared to
  151. answer all types of calls.  See your Courier manual for more info on the
  152. ATB0 and ATB1 commands.
  153.  
  154. Hayes owners
  155. ~~~~~~~~~~~~
  156. BGFAX has been tested with the Hayes Optima 288 V.FC modem and the V.34
  157. upgrade.
  158.  
  159. Make sure you are using the 3.10 ROMs in the V.FC model.  Use the ATI3
  160. command.  It will produce a multi-line response.  Look for...
  161.  
  162.     04-00621-310 27232 PASS      <-- Notice the "310", that means 3.10
  163.              ^^^
  164. ATI7 will produce a more human readable response, but it is not reliable.
  165. ATI7 will report the ROM version that ORIGINALLY was in the modem when it
  166. was manufactuered.
  167.  
  168. If you are using a 14400 version of the Optima or Accura, you will need
  169. to put a minus sign after the com port number so that BGFAX will use an
  170. alternate method of 19200-shifting.  (i.e., po=1- inside the BGFAX.CNF
  171. for COM1, Accura-style 19200 DTE shifting.)  Also, the 14400 Accura does
  172. not like the answer string of "AT+FAE=1;A" like its 28800 counterpart.
  173. You will need to use another initialize string of "AT+FAE=1" and use the
  174. regular answer string of "ATA".
  175.  
  176.  
  177. ZyXEL owners
  178. ~~~~~~~~~~~~
  179. See the included FD-ZYXEL.TXT file for an example of how to use the ZyXEL
  180. with FD 2.12/SW.
  181.  
  182. Basically, the init strings are:
  183.  
  184. ATZ
  185. AT#P713 555 1212
  186. AT#B1+FCLASS=6
  187.  
  188. And the answer string is "ATA".
  189.  
  190. The above strings basically use the ZyXEL's special fax mode.  People
  191. report greater success with that method, as compared to using ZyXEL's
  192. Class 2 implementation.
  193.  
  194. If you have trouble with BGFAX and the ZYXEL, you can always use REFAX,
  195. or the ZFAX software that comes with your modem.
  196.  
  197. If you want to send faxes with the ZyXEL 2864-ISDN modem with BGFAX, add
  198. a line in the BGFAX.CNF that says "ss=AT&O0".  That will make BGFAX send
  199. the command to the modem that activates the fax/modem/voice DTE channel
  200. rather than the ISDN DTE channel.
  201.  
  202.  
  203. Supra owners
  204. ~~~~~~~~~~~~
  205. I own a Supra 14400 with 1.8 ROMs myself.  I have not tested BGFAX with
  206. the Supra 14400 with the 'newer' 1.4 ROMs (the newer board layout) or with
  207. the Supra LC (14400, low cost alternative).
  208.  
  209. The Caller ID features in BGFAX's /HOST mode where developed using the
  210. Supra v.32bis (the older 1.8 series) as a reference.
  211.  
  212. If you are using a Supra 288 V.FC (-16 firmware), the adaptive answering
  213. is broken.  Call the Supra BBS and download the latest FLASH firmware for
  214. the V.FC modem to fix it.
  215.  
  216. I've heard that some Supra 288 V.34 modems where released with the -18
  217. firmware.  This firmware version has a bug that prevents it from receiving
  218. faxes properly at 9600 bps.  Return to an older version (like -15) or
  219. upgrade to a newer FLASH firmware (it is is available.)
  220.  
  221. The Supra 288 V.34 modem has very good adaptive answering.  It can even be
  222. tuned, which is unique only to Supra and Multitech.  The tuning is made by
  223. tweaking the S192 register.
  224.  
  225.     S192=2 (default)   'Bad' calls logged as "NO CARRIER"
  226.     S192=0 (better)    'Bad' calls logged as "FAX"
  227.  
  228. The default value will make the Supra V.34 do adaptive answering like the
  229. Supra V.32bis did.  In this case, the modem will wait for about 1 or 2
  230. seconds before starting a data mode handshake.  If a fax CNG tone is heard
  231. during the initial 1 to 2 second wait, the modem will respond "FAX" and
  232. shift into fax mode.  On bad data calls, the modem will properly log the
  233. failed call as "NO CARRIER".
  234.  
  235. So, what's bad about the default?  It sounds good, BUT... Many fax machines
  236. out there don't send CNG tones during the first 1-2 seconds.  For example,
  237. if a user tries to send a fax to you from a real-live fax machine, he or she
  238. must hit the 'START' button on some models to make a fax CNG tone.  Many
  239. times the person sending the fax will not hit 'START' until after they hear
  240. noises coming from the modem.  If you use S192=2 (the default), YOU WILL
  241. MISS THIS PARTICULIAR FAX CALL!
  242.  
  243. If you use the recommended S192=0 setting, the modem will report "FAX", and
  244. you WILL get this fax call.  If getting all fax calls are important, you
  245. should definately use S192=0.  So, there has to be a downside to this, right?
  246. Yes, there is...  If a bad modem handshake occurs, rather than getting a
  247. "NO CARRIER" result, you will get a "FAX" result.  This is the way that
  248. S192=0 is _supposed_ to work.  IT IS *NOT* A BUG IN THE MODEM.  Many people
  249. don't like 'false' FAX connects and that is why Supra choose to use S192=2
  250. as the default.  So, in summary, if you want reliable fax operation, use
  251. S192=0, just remember you will get the 'FAX' return result when it is
  252. actually a failed handshake of a data call.
  253.  
  254. Multitech owners
  255. ~~~~~~~~~~~~~~~~
  256. The Multitech offers adaptive answering tuning, just as the Supra V.34.
  257.  
  258.     AT+FAAMOD=0      see your manual for description
  259.     AT+FAAMOD=1      see your manual for description
  260.  
  261. The Multitech Class 2 mode will NOT shift to 19200 when receiving in fax
  262. mode.  Because of this, make sure you put a '!' after the com port to tell
  263. BGFAX that this modem will not need a 19200 DTE shift.  Example command line:
  264.  
  265.     bgfax /fax c:\bgfax 1! z      <-- keep locked at current rate
  266.  
  267. If you are able to receive a fax, but are unable to read the fax received
  268. from the Multitech, you might want to add the AT+FBOR=1 string to your
  269. initialization.
  270.  
  271. Zoom owners
  272. ~~~~~~~~~~~
  273. Some Zoom owners have experienced more reliable BGFAX operation when using
  274. the exclaimation point (!, bang) after the port.  This instructs BGFAX to
  275. NOT drop the port speed down to 19200 bps when in fax mode.  Almost all
  276. Class 2 fax modems require this shift.  SOME Zoom modems will not operate
  277. with BGFAX unless you use the "!" after the port.  SOME Zoom modems will
  278. NOT operate if you PUT the "!" after the port.  Just a little warning.
  279.  
  280.     bgfax /fax c:\bgfax 1 z       <-- change speed to 19200 when receivin
  281.     bgfax /fax c:\bgfax 1! z      <-- keep locked at current rate
  282.  
  283. If you are using a 28800 Zoom modem, make sure you are using at least
  284. firmware version 1.100.  (ATI3 will show you the version number.)
  285.  
  286. Zoom released the series 1.309 firmware for it's V.34 products in October
  287. of 1995.  This new firmware release corrects the adaptive answering problems
  288. that surfaced in Rockwell's V.FC and V.34 chipsets.  (As far as I know, the
  289. adaptive answering bug fix is only available for Zoom's V.34 modems.)
  290.  
  291.  
  292. PPI owners
  293. ~~~~~~~~~~
  294. Some of the earlier PPI modems do not include Class 2 fax.  You can buy an
  295. upgrade ROM for approximately $30 that will let you use BGFAX, however, it
  296. will only allow fax speeds up to 9600 rather than 14400.  If you want to
  297. use 14400 fax, you will have to get a new motherboard and datapump that
  298. will cost you about $100.  Most fax machines only support 9600 fax anyway
  299. so this is not that much of a problem.
  300.  
  301. Please note that most PPI owners are using the newer models that include
  302. both Class 1 and Class 2 fax at speeds up to 14400.  If you think you might
  303. have an older model, issue a "AT+FCLASS=?" command from your terminal
  304. program.  It it responds "0,1" you have an older model that needs the
  305. upgrade in order to use Class 2.  If it responds "0,1,2" you have a newer
  306. model and BGFAX should work fine.
  307.  
  308. It has been suggested to me by a member of PPI's tech support team, to tell
  309. all users to use the &D3 setting instead of the, more usually used &D2
  310. setting.  This &D3 setting seems to eliminate some 'odd' problems.
  311.  
  312. If you have the 2.17 version ROMs in your modem, you need to get it
  313. upgraded to 2.30.  Many people reported problems with the 2.17 firmware.
  314. Call PPI Tech Support for info on upgrading.  It should be free, but this
  315. policy may have changed with the recent Hayes fiasco.  Note that if you
  316. have an older FXSA [xA3] modem, you cannot upgrade the 2.17 to 2.30.  If
  317. you have this [xA3] model, you're out of luck.  (The number in brackets
  318. is given by the ATI3 command, and the "x" can be any number.)
  319.  
  320. If ATI3 reports [9R4] in brackets, you will have either 2.42 or 2.43
  321. firmware.  Be sure to add an S7=125 in your init string.
  322.  
  323. I've had a few ports that the PM144MT/HCII [xxRx] version 1.03 mistakes
  324. 2400 data callers as faxes.  I am not sure if the 2.02 version does this
  325. or not.
  326.  
  327. PM144FXH, [41R4] 1.03, report same 2400 problem
  328. PM144FXHC, [43R4] 1.54 seemed to work fine at 2400
  329.  
  330. One person claims the PPI's 288LCD fax mode is flawed with firmware 2.62
  331.  
  332. PC Logic owners
  333. ~~~~~~~~~~~~~~~
  334. The PC Logic adaptive answering seems to not work at all, in the 14400
  335. model.  I haven't tried it with their new v.32terbo modem.  My advice is
  336. to not try running BGFAX on the PC Logic.
  337.  
  338.  
  339. Hornet 28.8 VFC owners
  340. ~~~~~~~~~~~~~~~~~~~~~~
  341. I've seen two people with Hornet 28.8 VFC modems report they were getting
  342. +FHNG:25 error messages when trying to receive faxes.  The solution was
  343. to put an &K3 at the end of the last init strings.  Very strange.
  344.  
  345.  
  346. DesqView
  347. ~~~~~~~~
  348. If you have trouble SENDING faxes under DV, make sure...
  349.             "Optimize Communications=YES"
  350.  
  351. ...in your DV configuration screen.  Note that some people have told me
  352. this does not help at all, but others report it does make a difference.
  353.  
  354.  
  355. OS/2
  356. ~~~~
  357. You must be using Ray Gwinn's SIO communications driver.  BGFAX/2 has not
  358. been tested with the stock IBM COM.SYS drivers!
  359.  
  360. If you have trouble SENDING faxes under OS/2, make sure you use the native
  361. OS/2 version of BGFAX to do the sending.  The DOS version of BGFAX, if
  362. running in an OS/2 DOS-box, will have trouble using software based flow
  363. control on some modems because of the way SIO handles XON/XOFF characters
  364. when it is set for RTS/CTS flow control mode.  Using BGFAX2.EXE will solve
  365. that problem.
  366.  
  367. If you really want to use the DOS version of BGFAX to send faxes when using
  368. OS/2, change the "SIO_Mode_XON/XOFF" setting (see SIO's docs for more
  369. details) to "Received XON is flow control".
  370.  
  371. If you "lock" your com ports DTE rate with SIO, be sure to read the section
  372. in the BGFAX.DOC file which describes operation of the SU.EXE program.
  373.  
  374.  
  375. PC Board for OS/2
  376. ~~~~~~~~~~~~~~~~~
  377. PC Board for OS/2 is very new, but I am sure many of you are going to be
  378. using it before the next BGFAX release comes out.  BGFAX 1.50 is coming out
  379. before the full public release of PCB/2, and I know little about it, but
  380. there are a few things different about the OS/2 PCB setup from the DOS setup
  381. in relation to BGFAX.
  382.  
  383. In all of BGFAX's PC Board help files (PCB*.TXT), they always give examples
  384. like:  BGFAX /xxxx C:\BGFAX 1 Z
  385.  
  386. Where xxxx is some parameter, depending upon type of modem.  The "1" in the
  387. above would represent COM1.  In OS/2, com ports are handled via a "handle".
  388. So, instead of "1", you might say "h%pcbhandle%".
  389.  
  390. Example:  BGFAX2 /xxxx C:\BGFAX H%pcbhandle% Z
  391.  
  392. Where "H" tells BGFAX the number following is an OS/2 com handle, and where
  393. "%pcbhandle%" returns the value of the environment variable set by PC Board.
  394.  
  395. NOTE: I am not certain if that is the correct environment variable name.